Measurement Driver Download For Windows

-->

Having an issue with your display, audio, or touchpad? Whether you're working on an Alienware, Inspiron, Latitude, or other Dell product, driver updates keep your device running at top performance. Step 1: Identify your product above. Step 2: Run the detect drivers scan to see available updates. Step 3: Choose which driver updates to install.

Versions supported

  • Software and Driver Downloads NI provides downloadable software for NI products and both NI and third-party instrument drivers. We also offer downloadable camera network files and DataPlugins.
  • Download the latest drivers, firmware, and software for your HP Universal Print Driver for Windows - PCL 6.This is HP’s official website that will help automatically detect and download the correct drivers free of cost for your HP Computing and Printing products for Windows and Mac operating system.
  • Windows 10
  • Windows 8.1

Applies to

  • Device manufacturers of CDC Control devices

Microsoft-provided in-box driver (Usbser.sys) for your Communications and CDC Control device.

In Windows 10, the driver has been rewritten by using the Kernel-Mode Driver Framework that improves the overall stability of the driver.

  • Improved PnP and power management by the driver (such as, handling surprise removal).
  • Added power management features such as USB Selective Suspend.

In addition, UWP applications can now use the APIs provided by the new Windows.Devices.SerialCommunication namespace that allow apps to talk to these devices.

Usbser.sys installation

Load the Microsoft-provided in-box driver (Usbser.sys) for your Communications and CDC Control device.

Note

If you trying to install a USB device class driver included in Windows, you do not need to download the driver. They are installed automatically. If they are not installed automatically, contact the device manufacturer. For the list of USB device class driver included in Windows, see USB device class drivers included in Windows.

Windows 10

Driver

In Windows 10, a new INF, Usbser.inf, has been added to %Systemroot%Inf that loads Usbser.sys as the function device object (FDO) in the device stack. If your device belongs to the Communications and CDC Control device class, Usbser.sys is loaded automatically.You do not need to write your own INF to reference the driver. The driver is loaded based on a compatible ID match similar to other USB device class drivers included in Windows.

USBClass_02

USBClass_02&SubClass_02

  • If you want to load Usbser.sys automatically, set the class code to 02 and subclass code to 02 in the Device Descriptor. For more information, see USB communications device class. With this approach, you are not required to distribute INF files for your device because the system uses Usbser.inf.
  • If your device specifies class code 02 but a subclass code value other than 02, Usbser.sys does not load automatically. Pnp Manager tries to find a driver. If a suitable driver is not found, the device might not have a driver loaded. In this case, you might have to load your own driver or write an INF that references another in-box driver.
  • If your device specifies class and subclass codes to 02, and you want to load another driver instead of Usbser.sys, you have to write an INF that specifies the hardware ID of the device and the driver to install. For examples, look through the INF files included with sample drivers and find devices similar to your device. For information about INF sections, see Overview of INF Files.

Note

Microsoft encourages you to use in-box drivers whenever possible. On mobile editions of Windows, such as Windows 10 Mobile, only drivers that are part of the operating system are loaded. Unlike desktop editions, it is not possible to load a driver through an external driver package. With the new in-box INF, Usbser.sys is automatically loaded if a USB-to-serial device is detected on the mobile device.

Windows 8.1 and earlier versions

In Windows 8.1 and earlier versions of the operating system, Usbser.sys is not automatically loaded when a USB-to-serial device is attached to a computer. To load the driver, you need to write an INF that references the modem INF (mdmcpq.inf) by using the Include directive. The directive is required for instantiating the service, copying inbox binaries, and registering a device interface GUID that applications require to find the device and talk to it. That INF specifies 'Usbser' as a lower filter driver in a device stack.

The INF also needs to specify the device setup class as Modem to use mdmcpq.inf. Under the [Version] section of the INF, specify the Modem and the device class GUID. for details, see System-Supplied Device Setup Classes.

For more information, see this KB article.

Configure selective suspend for Usbser.sys

Starting in Windows 10, Usbser.sys supports USB Selective Suspend. It allows the attached USB-to-serial device to enter a low power state when not in use, while the system remains in the S0 state. When communication with the device resumes, the device can leave the Suspend state and resume Working state. The feature is disabled by default and can be enabled and configured by setting the IdleUsbSelectiveSuspendPolicy entry under this registry key:

To configure power management features of Usbser.sys, you can set IdleUsbSelectiveSuspendPolicy to:

  • '0x00000001': Enters selective suspend when idle, that is, when there are no active data transfers to or from the device.

  • '0x00000000': Enters selective suspend only when there are no open handles to the device.

That entry can be added in one of two ways:

  • Write an INF that references the install INF and add the registry entry in the HW.AddReg section.

  • Describe the registry entry in an extended properties OS feature descriptor. Add a custom property section that sets the bPropertyName field to a Unicode string, 'IdleUsbSelectiveSuspendPolicy' and wPropertyNameLength to 62 bytes. Set the bPropertyData field to '0x00000001' or '0x00000000'. The property values are stored as little-endian 32-bit integers.

    For more information, see Microsoft OS Descriptors.

Develop Windows applications for a USB CDC device

If you install Usbser.sys for the USB CDC device, here are the application programming model options:

Measurement Driver Download For Windows 8.1

  • Starting in Windows 10, a Windows app can send requests to Usbser.sys by using the Windows.Devices.SerialCommunication namespace. It defines Windows Runtime classes that can use to communicate with a USB CDC device through a serial port or some abstraction of a serial port. The classes provide functionality to discover such serial device, read and write data, and control serial-specific properties for flow control, such as setting baud rate, signal states.

  • In Windows 8.1 and earlier versions, you can write a Windows desktop application that opens a virtual COM port and communicates with the device. For more information, see:

    Win32 programming model:

    • .NET framework programming model:

Related topics

Links for the following software are provided on this page. Please read the 'Download procedure' and then download the software.

Important information regarding Gemalto HASP driver

Customers using Color Data Software SpectraMagic NX (Ver. 2.81 or earlier) or Color Data Software SpectraMagic DX (Ver. 1.21 or earlier) should update the HASP driver (software protection system driver from Gemalto NV) to Ver. 7.63 or later for improved security.
Click here for further information.

Download procedure

To download the desired software:

  1. Click on the link for the End User License Agreement for the desired software. (If there is no End User License Agreement link, click on the software title and go to step 3.)
  2. Read the End User License Agreement thoroughly. If you agree with this license, click [I Agree].
  3. Fill in the requested information in the Personal Information form that appears. Be careful that your email address is input correctly, since the download link will be sent to that email address.
  4. Click [Submit]. The personal information that you input will be shown for you to check.
  5. If the information is correct, click [Send].
  6. An email with the link to download the software you selected will be sent to the email address that you input in step 3. Click on the link in the email to download the software.

Color Data Software SpectraMagic NX

Ver. 3.10 (Combined Trial / Upgrade Edition)

Compatible instruments
SpectrophotometersCM-25cG, CM-26dG/26d/25d,
CM-3600A/3610A, CM-3630,
CM-3700A, CM-5, CM-700d/600d,
CM-2500c, CM-2600d/2500d, CM-3500d, CM-3600d/3610d, CM-3700d,
CM-512m3A/512m3
Chroma MetersCR-400/410, DP-400, CR-5
SpectrodensitometersFD-7/5

Upgrading: Customers who have purchased SpectraMagic NX can download the latest version free of charge. Before upgrading, please read the installation procedure.

Note: If the OS of the computer on which SpectraMagic NX is installed will be upgraded from Windows 7 to Windows 10, check the SpectraMagic NX version prior to upgrading the OS. If the SpectraMagic NX version is Ver. 2.6x or earlier, it cannot be used on Windows 10. Uninstall SpectraMagic NX before upgrading the OS, and then download and install the most recent version of SpectraMagic NX after upgrading the OS.

Trial Use: Customers who are considering the purchase of SpectraMagic NX can download the latest version and try it out for a 30-day trial period. After the trial period has ended, a license (protection key) should be purchased to continue using SpectraMagic NX. (If no license is purchased, only very limited functionality will be available after the trial period has expired.)

Languages available:
English, French, German, Italian, Portuguese, Spanish, Traditional Chinese, Simplified Chinese, Korean

Ver. 2.03 Upgrade Edition

Users of Windows® 2000 or of instruments not supported on later versions (CM-2002, CM-500 series excluding CM-512m3, CR-300/CR-200 series) can download the previous Ver. 2.03.

Note: Ver. 2.03 is not compatible with Windows® 7 or later OS versions.

Languages available:
English, French, German, Italian, Spanish, Korean

Configuration Tool CM-CT1

Ver. 1.20

Compatible instruments
SpectrophotometersCM-26dG/26d/25d, CM-25cG

Configuration Tool CM-CT1 can be used to connect the Spectrophotometer CM-26dG, CM-26d, CM-25d or CM-25cG to a computer for performing the following functions:

  • Setting of main instrument settings (excluding some unit-specific settings)
  • Data output
  • Setting of calibration data
  • Remote control of instrument

Color Data Software SpectraMagic DX

Ver. 1.27 (Combined Trial / Upgrade Edition)

Compatible instrumentsSpectrophotometer CM-M6

Customers who have purchased SpectraMagic DX can download the installer for latest version of the software here.
Customers who have not yet purchased a license can try out SpectraMagic DX for a limited trial period.

Languages available:
English, Japanese, German, French, Spanish, Italian, Portuguese, Russian, Turkish, Polish, Simplified Chinese, and Traditional Chinese (Selectable after installation)

Bluetooth Dongle Setting Tool (for CM-M6)

Ver. 1.00

This utility software is used to set up the Bluetooth Module CM-A219 for the Spectrophotometer CM-M6.

Languages available:
English

Accessory Software for CM-2600d

This software can be used to connect the Spectrophotometer CM-2500d / CM-2600d to a PC. Measurement data obtained with the Spectrophotometer can be output to an Excel spreadsheet or in text format.

Languages available:
English

Driver for USB-Serial Converter Cable (IF-A24 for CM-2600d series; CR-A105 for CR-400 series)

Sorry you need to have JavaScript enabled on your browser.

Ver. 1.02

This is the latest version of the driver for the USB-Serial Converter Cable (IF-A24 for Spectrophotometer CM-2600d, CM-2500d, and CM-2500c; CR-A105 for Chroma Meter CR-400 and CR-410).
For installation procedures, please refer to the instruction manual included in the download zip file.

Compatible Operating Systems:

  • Windows® 7 Professional 32-bit, 64-bit
  • Windows® 8.1 Pro 32-bit, 64-bit
  • Windows® 10 Pro 32-bit, 64-bit

User Calibration Software CM-S20w

Ver. 1.20

Customers who have purchased the CM-512m3A can download the latest version of the User Calibration Software CM-S20w. User Calibration Software CM-S20w is included as a standard accessory with the CM-512m3A.

Languages available:
English, Simplified Chinese

Gloss Meter Software

Ver. 1.00

This software can be used to connect the Gloss Meter Multi Gloss 268A, Uni Gloss 60A, Uni Gloss 60CT, and Uni Gloss 60S to a computer.

Languages available:
English, French, German, Italian, Japanese, Russian, Spanish, Simplified Chinese

Data Management Software FD-S1w

Ver. 1.12

Customers who have purchased the Spectrodensitometer FD-7 or FD-5 can download Data Management Software FD-S1w free of charge.
Data Management Software FD-S1w offers the following functions:

Measurement
  • Transfer of measurement data from the FD-7 or FD-5 to Excel® immediately after measurement.
  • Registration of color sets (see below) in the FD-7 or FD-5 for the instrument’s ISO Check (ISO 12467) and Target Match functions.
  • Storage of light source data measured with the FD-7 as a computer file and registration of that data as User Illuminant on other FD-7 or FD-5 instruments.

Languages available:
English, Simplified Chinese

Color Set Files

Customers using Data Management Software FD-S1w can download the latest color set data files. The data in these files can then be registered on the FD-7 or FD-5 using Data Management Software FD-S1w.
The following color set groups are available:
GRACoL, ISO12647, Japan Color, PSO, SWOP

  • These color set files were last updated in June 2013 and are the same as the files installed with Data Management Software FD-S1w Ver. 1.10 or later.

Measurement Driver Download For Windows

Measurement Utility Software FD-S2w

Windows: Ver. 1.60
OS X / macOS: Ver. 1.61

Customers who have purchased the Auto Scan Spectrophotometer FD-9 can download Measurement Utility Software FD-S2w free of charge.
Measurement Utility Software FD-S2w offers the following functions:

  • Scanning of color charts using the FD-9 and display of measurement data (spectral data, colorimetric data, and density data) for each color patch on the scanned color charts.
  • Calculation of colorimetric measurement data under user illuminants using user illuminant data uploaded from the Spectrophotometer CL-500A or Spectrodensitometer FD-7.(User illuminant data can be measured using the Spectrophotometer CL-500A or Spectrodensitometer FD-7.
  • Measurement of charts for adjustment of density balance and color density control on specific models of KONICA MINOLTA bizhub PRESS series printers. (Customers owning a Spectrodensitometer FD-5 BT or FD-5 BT2 can also download this software free of charge in order to use this function.)

Languages available:
English, Japanese, Simplified Chinese, German, French, Spanish

Job templates for Color Management Software basICColor series Catch

Sorry you need to have JavaScript enabled on your browser.

Ver. 2.00

Customers who have purchased Color Management Software basICColor series Catch can download these templates and use them with Catch.